Can Globe Valves And Gate Valves Be Used Together?

Jan. 08, 2020

Globe valves, gate valves, butterfly valves, check valves and Ball Valves are all indispensable control components in various piping systems. Every valve has a difference in appearance, structure and even functional use. However, the globe valves and the gate valve have some similarities in shape, and both have the function of cutting off in the pipeline, so there will be many friends who do not have much contact with the valve to confuse the two. The Handwheel Forged Steel Gate Valve Manufacturer introduces the difference between a globe valve and a gate valve.


1. Structurally

Pay attention to the selection when the installation space is limited:

The gate valve can be tightly closed to the sealing surface by the pressure of the medium, so as to achieve the effect of no leakage. When opening and closing, the valve core and the seat sealing surface always contact and rub against each other, so the sealing surface is easy to wear. When the gate valve is close to close, the pressure difference between the front and back of the pipeline is very large, which makes the sealing surface wear more serious.

The structure of the gate valve is more complicated than that of the cut-off valve. From the perspective of the appearance, the gate valve is higher than the cut-off valve, and the cut-off valve is longer than the gate valve. In addition, the gate valve is divided into a bright rod and a dark rod, while the globe valve does not.


2. Working principle

When the shut-off valve is opened and closed, the valve stem is raised, that is, when the hand wheel is turned, the hand wheel will rotate and lift along with the valve stem. The gate valve rotates the hand wheel to make the valve stem move up and down, and the position of the hand wheel does not change.

The flow varies, and gate valves require full opening or full closing, while stop valves do not. Shut-off valves have prescribed inlet and outlet directions, and gate valves do not have inlet and outlet direction requirements.

In addition, the gate valve has only two states of fully open or fully closed, and the stroke of the gate opening and closing is large, and the opening and closing time is long. The moving stroke of the valve plate of the shut-off valve is much smaller, and the valve plate of the shut-off valve can be stopped somewhere during the movement for flow adjustment. The gate valve can only be used for cut-off use and has no other functions.

Stainless Steel Thread Globe Valve

Stainless Steel Thread Globe Valve


3. Performance difference

The shut-off valve can be used for both shut-off and flow adjustment. The fluid resistance of the globe valve is relatively large, and it is laborious to open and close, but because the distance between the valve plate and the sealing surface is short, the opening and closing stroke is short.

Because the gate valve can only be fully opened and fully closed, when it is fully opened, the medium flow resistance in the valve body channel is almost 0, so the opening and closing of the gate valve will be very labor-saving, but the distance between the gate and the sealing surface is long, and the opening and closing time is long.


4. Installation and flow

The gate valve has the same effect in both directions. There is no requirement for the direction of the inlet and outlet, and the medium can flow in both directions. The shut-off valve needs to be installed in strict accordance with the direction indicated by the arrow on the valve body. The flow direction of the shut-off valve is always top-down.

The shut-off valve is low-in and high-out. From the outside, it is obvious that the pipeline is not on a phase horizontal line. The gate valve runner is on a horizontal line. The gate valve has a longer stroke than the shut-off valve.

From the point of view of flow resistance, the flow resistance of the gate valve is small and the flow resistance of the stop valve is large when it is fully opened. When opening and closing, the valve must be closed forcibly to achieve the seal. The valve core of the shut-off valve only contacts the sealing surface when it is fully closed, so the wear of the sealing surface is very small. Due to the large flow force, the stop valve with an actuator should pay attention to the torque control mechanism adjustment.


5. Sealed

The sealing surface of the globe valve is a small trapezoidal side of the valve core. Once the valve core is detached, it is equivalent to the valve closing. The gate valve is sealed by the side of the valve core. A valve is like a valve closing.


The above is the difference between globe valve and gate valve introduced by the supplier of Stainless Steel Thread Globe Valve. I hope it can help everyone.

Xintai Valve Group Co., Ltd.

Hot products: Stainless Steel of Ball Valve, Gate Valve, Check valve and Globe Valve

Tel.: +86 577 8689 9158 | Mob.: +86 177 0587 1779 | Fax: +86 577 8551 6299 | E-mail: xtvalve3@xintaivalves.com

Skype: xtvalve3 | WhatsApp: +86 177 0587 1779

QQ: 2881757190 | WeChat: 17705871779

R&D Precision Add: No.16 Xingyu Road, airport Area Wenzhou City,Zhejiang, China.

Casting Add: Dushan Part, Center industrial Park LongWan, Wenzhou City, Zhejiang, China.

Copyright © Xintai Valve Group Co., Ltd. All Rights Reserved