{"id":15149,"date":"2026-05-04T08:00:00","date_gmt":"2026-05-04T00:00:00","guid":{"rendered":"https:\/\/www.xintaivalves.com\/?p=15149"},"modified":"2026-05-15T08:49:23","modified_gmt":"2026-05-15T00:49:23","slug":"what-is-butterfly-valve-water-supply-uses","status":"publish","type":"post","link":"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/","title":{"rendered":"Katup Kupu-Kupu Pengolahan Air: Jenis, Prinsip Kerja, dan Aplikasi Pasokan Air"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Daftar isi<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Alihkan Daftar Isi\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Beralih<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 eztoc-toggle-hide-by-default' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#What_is_a_Water_Treatment_Butterfly_Valve\" >Apa itu Katup Kupu-Kupu Pengolahan Air?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#Butterfly_Valve_Parts_Diagram_Key_Components_Explained\" >Diagram Bagian Katup Kupu-Kupu: Komponen Kunci Dijelaskan<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#1_Valve_Body\" >1. Badan Katup<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#2_Disc\" >2. Cakram&nbsp;<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#3_Stem_or_Shaft\" >3. Batang atau Poros<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#4_Seat\" >4. Dudukan<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#5_Seals_and_O-Rings\" >5. Segel dan Cincin O<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#6_Actuation_Interface\" >6. Antarmuka Aktuasi<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#Butterfly_Valve_Working_Principle\" >Prinsip Kerja Katup Kupu-Kupu<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#Choosing_the_Right_Butterfly_Valve_Types_for_your_Project\" >Memilih Jenis Katup Kupu-Kupu yang Tepat untuk Proyek Anda<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#Water_Treatment_Butterfly_Valve_Installation_Connection_and_Actuation_Methods\" >Pemasangan Katup Kupu-Kupu Pengolahan Air: Metode Koneksi dan Aktuasi<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#Where_Is_a_Water_Treatment_Butterfly_Valve_Used_in_Water_Supply\" >Di Mana Katup Kupu-Kupu Pengolahan Air Digunakan dalam Pasokan Air?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#Butterfly_Valve_Advantages_and_Disadvantages\" >Kelebihan dan Kekurangan Katup Kupu-Kupu<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#Advantages\" >Keuntungan<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-15\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#Disadvantages\" >Kekurangan<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-16\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#Installation_and_Maintenance_Tips\" >Tips Instalasi dan Perawatan<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-17\" href=\"https:\/\/www.xintaivalves.com\/id\/blog\/butterfly-valve\/what-is-butterfly-valve-water-supply-uses\/#Conclusion\" >Kesimpulan<\/a><\/li><\/ul><\/nav><\/div>\n\n<p class=\"wp-block-paragraph\">Dalam jaringan air kota, air bergerak melalui ratusan kilometer pipa. Pipa-pipa bergerak dari instalasi pengolahan ke rumah, pabrik, dan hidran kebakaran.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sistem air juga membutuhkan sinyal dan jalan masuk agar tetap teratur. Di sinilah <a href=\"https:\/\/www.xintaivalves.com\/id\/butterfly-valve-collection\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>jenis katup kupu-kupu<\/strong><\/a> masuk. Katup mengontrol ke mana air pergi dan seberapa cepat ia mengalir.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Panduan ini membahas apa yang perlu diketahui oleh seorang insinyur proyek atau profesional lapangan tentang prinsip kerja katup kupu-kupu dan berbagai jenisnya. Panduan ini juga membahas kelebihan dan kekurangan katup kupu-kupu, dan bagaimana berbagai jenis katup kupu-kupu digunakan dalam sistem pasokan air.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"What_is_a_Water_Treatment_Butterfly_Valve\"><\/span>Apa itu Katup Kupu-Kupu Pengolahan Air?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Katup kupu-kupu mengontrol fluida dengan memutar cakram datar 90 derajat di dalam badan pipa. Ia berputar dalam seperempat putaran. Penutupan katup terjadi ketika cakram tegak lurus dengan jalur aliran. Untuk membuka katup, cakram diputar sejajar dengan aliran.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Nama katup berasal dari tampilan cakram yang menyerupai sayap saat berputar dari batangnya. Rotasi 90 derajat memberikan aktuasi cepat untuk isolasi aliran segera.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Katup kupu-kupu direkomendasikan untuk pasokan air, distribusi air, sistem pengumpulan, stasiun pompa, dan instalasi pengolahan air. Katup ini dicirikan oleh badan yang ringkas, bobot ringan, dan aktuasi cepat. Hal ini menjadikannya pilihan utama untuk pipa DN 200 (8 inci) dan lebih besar.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Butterfly_Valve_Parts_Diagram_Key_Components_Explained\"><\/span>Diagram Bagian Katup Kupu-Kupu: Komponen Kunci Dijelaskan<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"512\" src=\"https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Key-Components-Explained-1024x512.webp\" alt=\"Katup kupu-kupu dengan aktuator komponen katup utama\" class=\"wp-image-15150\" srcset=\"https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Key-Components-Explained-1024x512.webp 1024w, https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Key-Components-Explained-300x150.webp 300w, https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Key-Components-Explained-768x384.webp 768w, https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Key-Components-Explained-18x9.webp 18w, https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Key-Components-Explained.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Bagian ini membahas komponen-komponen utama yang akan membantu pembeli menentukan konfigurasi yang tepat. Memahami bagian-bagian utama juga membantu kru pemeliharaan mengidentifikasi bagian mana yang cepat aus.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"1_Valve_Body\"><\/span>1. Badan Katup<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ini adalah selubung luar yang dipasang di antara atau pada flensa pipa. Bahan standar dalam layanan air adalah besi ulet GGG50 sesuai EN 1563 dengan lapisan bubuk epoksi yang terikat fusi (minimal 250 mikron). Lapisan epoksi melindungi dari korosi dan mencegah kontaminasi air minum.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"2_Disc\"><\/span>2. Cakram&nbsp;<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Elemen berputar ini seperti gerbang yang menghentikan atau mengizinkan aliran. Dalam aplikasi air, cakram biasanya terbuat dari besi ulet dengan <a href=\"https:\/\/www.xintaivalves.com\/id\/blog\/304-vs-316-stainless-steel-gate-valve\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.xintaivalves.com\/blog\/304-vs-316-stainless-steel-gate-valve\/\" rel=\"noreferrer noopener\">baja tahan karat 316<\/a> tepi yang dilas. Tepi baja tahan karat memberikan permukaan penyegelan tahan korosi yang tahan terhadap aksi abrasif air yang mengalir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"3_Stem_or_Shaft\"><\/span>3. Batang atau Poros<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Batang menghubungkan cakram ke pegangan atau aktuator eksternal. Dalam <strong>katup kupu-kupu dengan aktuator, <\/strong>desain batang dua bagian memungkinkan Anda melepas poros atas untuk pemeliharaan. Membongkar seluruh badan katup tidak diperlukan. Bahan standar yang digunakan untuk mencegah korosi adalah baja tahan karat 316.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"4_Seat\"><\/span>4. Dudukan<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dudukan adalah titik pencegahan kebocoran utama. Ini adalah segel internal tempat cakram menekan saat katup tertutup. Bahan dudukan umum termasuk karet EPDM, PTFE, dan NBR. Ini tergantung pada jenis air yang berbeda.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"5_Seals_and_O-Rings\"><\/span>5. Segel dan Cincin O<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Beberapa O-ring menyegel batang di mana ia keluar dari badan katup. Ini mencegah kebocoran di sepanjang poros. Desain modern menggunakan konfigurasi O-ring bertumpuk. Jika satu segel rusak, segel lainnya mempertahankan integritas tekanan hingga pemeliharaan terjadwal berikutnya.&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"6_Actuation_Interface\"><\/span>6. Antarmuka Aktuasi<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bagian atas batang terhubung ke tuas, roda tangan, gearbox, atau aktuator. Flensa dipasang sesuai dengan ISO 5210 (pemasangan aktuator multi-putaran) atau ISO 5211 (pemasangan aktuator seperempat putaran).&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Butterfly_Valve_Working_Principle\"><\/span>Prinsip Kerja Katup Kupu-Kupu<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bagaimana cara kerja katup kupu-kupu? Prinsip kerjanya lugas. Cakram berada di dalam pipa, terpasang pada batang tengah.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dalam posisi tertutup, ia menciptakan segel ketika cakram tegak lurus terhadap aliran fluida dan menekan dudukan.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dalam posisi terbuka, aktuator memutar batang 90 derajat, dan cakram berputar bersamanya. Cakram sejajar dengan arah aliran. Air kini dapat mengalir bebas di sekitar tepi tipis cakram.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Dalam rotasi parsial, antara 0 dan 90 derajat, ia juga memungkinkan pengaturan aliran penuh. Hubungan antara sudut cakram dan laju aliran mengikuti salah satu pola ini:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u00b7<\/strong>Aliran Hampir Linear \u2013 menunjukkan posisi cakram yang sesuai langsung dengan laju aliran. Pada bukaan 60%, sekitar 60% aliran maksimum melewatinya. Ini umum dalam desain eksentrik ganda.&nbsp;<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Aliran Buka Cepat<strong> \u2013 <\/strong>menunjukkan peningkatan aliran yang cepat dalam 30 hingga 40 derajat pembukaan pertama. Pergerakan tambahan yang lebih kecil memberikan perubahan yang lebih sedikit pada sudut yang lebih tinggi. Ini umum dalam desain konsentris standar.&nbsp;<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Choosing_the_Right_Butterfly_Valve_Types_for_your_Project\"><\/span>Memilih Jenis Katup Kupu-Kupu yang Tepat untuk Proyek Anda<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Jenis katup yang berbeda berkinerja berbeda. Jenis yang benar tergantung pada hal berikut:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ukuran pipa<\/li>\n\n\n\n<li>Tekanan operasi<\/li>\n\n\n\n<li>Persyaratan kelas penutupan<\/li>\n\n\n\n<li>Frekuensi operasi katup<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Di bawah ini adalah tabel yang merangkum berbagai jenis katup, spesifikasi, dan aplikasinya:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Fitur<\/strong><\/td><td><strong>Konsentris<\/strong><\/td><td><strong>Eksentrik Ganda<\/strong><\/td><td><strong>Eksentrik Tiga<\/strong><\/td><\/tr><tr><td><strong>Keausan dudukan<\/strong><\/td><td>Lebih tinggi<\/td><td>Lebih rendah<\/td><td>Minimal<\/td><\/tr><tr><td><strong>Torsi pengoperasian<\/strong><\/td><td>Lebih tinggi<\/td><td>Lebih rendah<\/td><td>Terendah<\/td><\/tr><tr><td><strong>Tekanan maksimum<\/strong><\/td><td>PN 10 (145 psi)<\/td><td>PN 16 (232 psi)<\/td><td>PN 40 (580 psi)<\/td><\/tr><tr><td><strong>Kelas penutupan<\/strong><\/td><td>Kelas IV\u2013V<\/td><td>Kelas V\u2013VI<\/td><td>Kelas VI \/ EN 12266-A<\/td><\/tr><tr><td><strong>Rentang ukuran tipikal<\/strong><\/td><td>DN 50\u2013600<\/td><td>DN 150\u20131600<\/td><td>DN 150\u20132500<\/td><\/tr><tr><td><strong>Penggunaan tipikal<\/strong><\/td><td>Irigasi, tekanan rendah<\/td><td>Pipa air kota<\/td><td>Tekanan tinggi, kritis<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Water_Treatment_Butterfly_Valve_Installation_Connection_and_Actuation_Methods\"><\/span>Pemasangan Katup Kupu-Kupu Pengolahan Air: Metode Koneksi dan Aktuasi<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"512\" src=\"https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Connection-and-Actuation-Methods-1024x512.webp\" alt=\"Diagram bagian katup kupu-kupu gaya koneksi dan metode aktuasi\" class=\"wp-image-15151\" srcset=\"https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Connection-and-Actuation-Methods-1024x512.webp 1024w, https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Connection-and-Actuation-Methods-300x150.webp 300w, https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Connection-and-Actuation-Methods-768x384.webp 768w, https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Connection-and-Actuation-Methods-18x9.webp 18w, https:\/\/www.xintaivalves.com\/wp-content\/uploads\/2026\/05\/Connection-and-Actuation-Methods.webp 1200w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Memilih gaya koneksi yang tepat sangat penting untuk <a href=\"https:\/\/www.xintaivalves.com\/id\/valve-cv-calculator-flow-coefficient-for-valve-sizing\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>pemasangan katup kupu-kupu pengolahan air<\/strong><\/a> dan pemeliharaan di masa mendatang.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Gaya Wafer:<\/strong> Gaya ini pas di antara flensa pipa. Ini adalah yang paling ringkas dan hemat biaya. Namun, ini tidak cocok untuk layanan ujung buntu.<\/li>\n\n\n\n<li><strong>Gaya Lug:<\/strong> Gaya ini memiliki lug berulir. Ini memungkinkan satu sisi jalur pipa dilepas tanpa mengganggu sisi lainnya. Ini ideal untuk pengaturan yang ramah perawatan.<\/li>\n\n\n\n<li><strong>Double Flanged:<\/strong> Gaya ini mencakup flensa sendiri. Ini juga memberikan koneksi terkuat untuk pipa berdiameter besar (24 inci ke atas).<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Untuk sistem otomatis, <strong>katup kupu-kupu dengan aktuator<\/strong> seringkali diperlukan. Anda dapat memilih dari aktuator listrik untuk integrasi SCADA, aktuator pneumatik untuk respons cepat, atau aktuator hidrolik untuk aplikasi torsi sangat tinggi.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Where_Is_a_Water_Treatment_Butterfly_Valve_Used_in_Water_Supply\"><\/span>Di Mana Katup Kupu-Kupu Pengolahan Air Digunakan dalam Pasokan Air?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Katup kontrol aliran pengolahan air muncul di setiap tahap jaringan air modern.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tabel di bawah merangkum jenis katup spesifik, spesifikasi, dan di mana katup tersebut umum digunakan:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Sektor Aplikasi<\/strong><\/td><td><strong>Kasus Penggunaan Spesifik<\/strong><\/td><td><strong>Ukuran &amp; Tipe Katup Khas<\/strong><\/td><td><strong>Persyaratan Teknis Utama<\/strong><\/td><\/tr><tr><td>Jaringan Air Kota<\/td><td>Isolasi transmisi dan distribusi<\/td><td>DN 600 \u2013 DN 2500; Ganda atau Tiga Eksentrik<\/td><td>Peringkat tekanan tinggi (PN 16\u2013PN 25); Roda tangan manual yang dioperasikan gearbox.<\/td><\/tr><tr><td>Instalasi Pengolahan Air<\/td><td>Pengambilan air baku, pencucian filter balik, dosis kimia<\/td><td>DN 50 \u2013 DN 2000; Konsentris atau Ganda Eksentrik<\/td><td>Dudukan PTFE untuk bahan kimia; Aktuator listrik untuk siklus pencucian balik otomatis.<\/td><\/tr><tr><td>Stasiun Pompa<\/td><td>Isolasi hisap\/buang pompa; bypass aliran<\/td><td>Berbagai; Ganda Eksentrik<\/td><td>Dudukan sesuai AWWA C504; Aktuator pengembalian pegas yang aman saat gagal untuk keadaan darurat.<\/td><\/tr><tr><td>Reservoir &amp; Penyimpanan<\/td><td>Siklus pengisian dan pengosongan masuk\/keluar; isolasi tangki<\/td><td>Berbagai; Ditentukan oleh tekanan statis<\/td><td>Kelas tekanan dipilih berdasarkan ketinggian (misalnya, PN 10 untuk ketinggian 30m).<\/td><\/tr><tr><td>Manajemen Tekanan<\/td><td>Kontrol batas zona (Area Pengukuran Distrik)<\/td><td>Berbagai; Tipe berkinerja tinggi<\/td><td>Aktuator listrik untuk penyeimbangan tekanan otomatis dan pencegahan lonjakan.<\/td><\/tr><tr><td>Proteksi Kebakaran<\/td><td>Peringkat tekanan tinggi (PN 16\u2013PN 25); Roda tangan manual yang dioperasikan dengan gearbox.<\/td><td>Sesuai NFPA 13<\/td><td>Harus menyertakan mekanisme penguncian atau sakelar tamper untuk pemantauan posisi.<\/td><\/tr><tr><td><a href=\"https:\/\/www.xintaivalves.com\/id\/blog\/wastewater-treatment-methods\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.xintaivalves.com\/blog\/wastewater-treatment-methods\/\" rel=\"noreferrer noopener\">Pengolahan air limbah<\/a><\/td><td>Isolasi masuk, bak aerasi, kontrol keluar<\/td><td>Desain dudukan yang diperkuat<\/td><td>Karet durometer yang lebih keras dan lapisan epoksi\/poliuretan anti-korosif.<\/td><\/tr><tr><td>Proses Industri<\/td><td>Menara pendingin, air proses manufaktur<\/td><td>Berbagai; Pilihan bodi baja tahan karat<\/td><td>Bahan dudukan tahan bahan kimia seperti PTFE atau FKM untuk kimia agresif.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Butterfly_Valve_Advantages_and_Disadvantages\"><\/span>Kelebihan dan Kekurangan Katup Kupu-Kupu<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Saat mengevaluasi <strong>katup kupu-kupu <a href=\"https:\/\/www.xintaivalves.com\/id\/blog\/understanding-the-key-differences-between-gate-valve-and-butterfly-valve\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.xintaivalves.com\/blog\/understanding-the-key-differences-between-gate-valve-and-butterfly-valve\/\" rel=\"noreferrer noopener\">keuntungan dan kerugian<\/a><\/strong>, manfaat untuk proyek air skala besar jelas:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Advantages\"><\/span>Keuntungan<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Desainnya yang ringkas memakan ruang sekitar sepertiga dari katup gerbang.&nbsp;<\/li>\n\n\n\n<li>Pada ukuran DN 200 ke atas, harganya efisien karena biayanya 30 hingga 50% lebih murah daripada katup gerbang.&nbsp;<\/li>\n\n\n\n<li>Hambatan minimal mengurangi biaya energi pompa dan memastikan penurunan tekanan yang rendah.&nbsp;<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Disadvantages\"><\/span>Kekurangan<span class=\"ez-toc-section-end\"><\/span><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cakram tetap berada di aliran. Ini mencegah penggunaan babi pembersih.<\/li>\n\n\n\n<li>Pengekangan kecepatan tinggi dapat menyebabkan risiko kavitasi dan kerusakan cakram.<\/li>\n<\/ul>\n\n\n\n<style>\n  .hero-card {\n    display: flex;\n    flex-wrap: wrap;\n    align-items: center;\n    background: #f7f8fa;\n    border-radius: 16px;\n    box-shadow: 0 6px 20px rgba(0, 0, 0, 0.05);\n    padding: 24px;\n    max-width: 900px;\n    margin: 40px auto;\n    font-family: Arial, sans-serif;\n    text-decoration: none;\n    color: inherit;\n    font-family: 'Poppins';\n    transition: transform 0.2s ease-in-out;\n  }\n\n  .hero-card:hover {\n    transform: translateY(-2px);\n  }\n\n  .hero-image {\n    width: 220px;\n    height: auto;\n    border-radius: 12px;\n    object-fit: cover;\n    flex-shrink: 0;\n  }\n\n  .hero-content {\n    padding-left: 24px;\n    flex: 1;\n    min-width: 260px;\n  }\n\n  .hero-title {\n    font-size: 1.6rem;\n    font-weight: bold;\n    margin-bottom: 12px;\n    color: #222;\n    font-family: 'Poppins';\n  }\n\n  .hero-description {\n    font-size: 1rem;\n    color: #555;\n    margin-bottom: 18px;\n    line-height: 1.5;\n  }\n\n  .hero-link {\n    display: inline-block;\n    padding: 10px 20px;\n    background-color: #D70C19;\n    color: #fff;\n    text-decoration: none;\n    border-radius: 8px;\n    font-weight: bold;\n    transition: background 0.2s ease-in-out;\n  }\n\n  .hero-link:hover {\n    background-color: #b30a15;\n  }\n\n  @media (max-width: 640px) {\n    .hero-card {\n      flex-direction: column;\n      text-align: center;\n    }\n\n    .hero-content {\n      padding-left: 0;\n      padding-top: 20px;\n    }\n\n    .hero-image {\n      width: 100%;\n      max-width: 280px;\n    }\n  }\n<\/style>\n\n<a class=\"hero-card\" href=\"https:\/\/www.xintaivalves.com\/id\/products\/centerline-wafer-type-butterfly-valve\/\" target=\"_blank\" rel=\"noopener\">\n  <img decoding=\"async\" class=\"hero-image\" src=\"https:\/\/xintaivalves.com\/wp-content\/uploads\/2022\/02\/%E6%9C%AA%E6%A0%87%E9%A2%98-2-1.jpg\" alt=\"CENTERLINE WAFER TYPE SOFT SEAL BUTTERFLY VALVE\">\n  <div class=\"hero-content\">\n    <div class=\"hero-title\">CENTERLINE WAFER TYPE SOFT SEAL BUTTERFLY VALVE<\/div>\n    <div class=\"hero-description\">\n      Katup kupu-kupu adalah perangkat profil rendah yang digunakan dalam proses industri. Relatif tipis, yang berarti dapat menempati lebih sedikit ruang dalam saluran pipa daripada jenis katup lainnya.\n    <\/div>\n    <span class=\"hero-link\">Jelajahi Produk &amp; Solusi<\/span>\n  <\/div>\n<\/a>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Installation_and_Maintenance_Tips\"><\/span>Tips Instalasi dan Perawatan<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sesuai <strong>pemasangan katup kupu-kupu pengolahan air<\/strong> mencegah kebocoran dini. Selama pemasangan dan pemeliharaan, flensa pipa harus selalu dibersihkan. Sebelum mengencangkan baut, selalu periksa ketidaksejajaran. Gunakan urutan pengencangan pola bintang untuk memastikan tekanan penyegelan yang merata.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Untuk keandalan jangka panjang, lakukan <a href=\"https:\/\/www.xintaivalves.com\/id\/products\/api-609-butterfly-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>penggantian katup kupu-kupu pengolahan air<\/strong><\/a> jika dudukan tidak lagi menyegel sepenuhnya. Pemeliharaan rutin harus mencakup pengoperasian katup setiap bulan untuk mencegah macet, terutama untuk unit isolasi darurat yang jarang digunakan.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Conclusion\"><\/span>Kesimpulan<span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.xintaivalves.com\/id\/contact\/\" target=\"_blank\" rel=\"noreferrer noopener\">Katup Xintai<\/a>, produsen katup sejak 1998, menawarkan <strong>katup kupu-kupu pengolahan air <\/strong>unit untuk proyek infrastruktur air Anda.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Memilih <strong>katup kupu-kupu pengolahan air terbaik<\/strong> memerlukan pemilihan material yang memenuhi peringkat tekanan spesifik proyek seperti PN 16. Ini melibatkan penentuan komponen seperti badan besi ulet dan dudukan EPDM untuk memenuhi persyaratan korosi yang unik. Anda juga harus memilih gaya aktuasi dan koneksi yang tepat untuk kebutuhan proyek spesifik Anda.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fe48e5de wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50\"><a class=\"wp-block-button__link has-white-color has-text-color has-background has-link-color has-medium-font-size has-custom-font-size wp-element-button\" href=\"https:\/\/www.xintaivalves.com\/id\/contact\/\" style=\"background-color:#b30a15\" target=\"_blank\" rel=\"noreferrer noopener\">Dapatkan Penawaran Gratis<\/a><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>In a city\u2019s water network, the water moves through hundreds of kilometers of pipes. The pipes move from treatment plants to homes, factories, and fire hydrants.&nbsp; The water system also needs signals and on-ramps to stay orderly. This is where the butterfly valve types come in. The valves control where the water goes and how [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":15152,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[233],"tags":[],"class_list":["post-15149","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-butterfly-valve"],"_links":{"self":[{"href":"https:\/\/www.xintaivalves.com\/id\/wp-json\/wp\/v2\/posts\/15149","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.xintaivalves.com\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.xintaivalves.com\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.xintaivalves.com\/id\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.xintaivalves.com\/id\/wp-json\/wp\/v2\/comments?post=15149"}],"version-history":[{"count":4,"href":"https:\/\/www.xintaivalves.com\/id\/wp-json\/wp\/v2\/posts\/15149\/revisions"}],"predecessor-version":[{"id":15157,"href":"https:\/\/www.xintaivalves.com\/id\/wp-json\/wp\/v2\/posts\/15149\/revisions\/15157"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.xintaivalves.com\/id\/wp-json\/wp\/v2\/media\/15152"}],"wp:attachment":[{"href":"https:\/\/www.xintaivalves.com\/id\/wp-json\/wp\/v2\/media?parent=15149"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.xintaivalves.com\/id\/wp-json\/wp\/v2\/categories?post=15149"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.xintaivalves.com\/id\/wp-json\/wp\/v2\/tags?post=15149"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}