{"id":13707,"date":"2025-10-13T15:02:37","date_gmt":"2025-10-13T07:02:37","guid":{"rendered":"https:\/\/www.xintaivalves.com\/?p=13707"},"modified":"2025-10-13T15:02:39","modified_gmt":"2025-10-13T07:02:39","slug":"iso-10497-valve-fire-type-testing-requirements","status":"publish","type":"post","link":"https:\/\/www.xintaivalves.com\/tr\/blog\/iso-10497-valve-fire-type-testing-requirements\/","title":{"rendered":"ISO 10497 Vanalar\u0131n Yang\u0131n Tipi Test Gereksinimleri Nelerdir?"},"content":{"rendered":"<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_86 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u0130\u00e7indekiler<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"\u0130\u00e7indekiler Tablosunu A\u00e7\/Kapat\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">De\u011fi\u015ftir<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 eztoc-toggle-hide-by-default' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.xintaivalves.com\/tr\/blog\/iso-10497-valve-fire-type-testing-requirements\/#Purpose_and_Scope_of_ISO_10497\" >ISO 10497&#039;nin Amac\u0131 ve Kapsam\u0131<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.xintaivalves.com\/tr\/blog\/iso-10497-valve-fire-type-testing-requirements\/#Key_Test_Conditions_and_Procedures\" >Temel Test Ko\u015fullar\u0131 ve Prosed\u00fcrleri<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.xintaivalves.com\/tr\/blog\/iso-10497-valve-fire-type-testing-requirements\/#Performance_Criteria_and_Acceptance_Limits\" >Performans Kriterleri ve Kabul Limitleri<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/www.xintaivalves.com\/tr\/blog\/iso-10497-valve-fire-type-testing-requirements\/#Qualification_and_Coverage_Rules\" >Nitelik ve Kapsam Kurallar\u0131<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/www.xintaivalves.com\/tr\/blog\/iso-10497-valve-fire-type-testing-requirements\/#Practical_Applications_for_Valve_Selection\" >Vana Se\u00e7imi \u0130\u00e7in Pratik Uygulamalar<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/www.xintaivalves.com\/tr\/blog\/iso-10497-valve-fire-type-testing-requirements\/#Manufacturing_Excellence_for_Fire_Safe_Applications\" >Yang\u0131na Dayan\u0131kl\u0131 Uygulamalar i\u00e7in \u00dcretim M\u00fckemmelli\u011fi<\/a><\/li><\/ul><\/nav><\/div>\n\n<p class=\"wp-block-paragraph\">ISO 10497 yang\u0131na dayan\u0131kl\u0131 vana testi, vanalar i\u00e7in yang\u0131n test gerekliliklerini belirleyen uluslararas\u0131 bir standartt\u0131r. Bu standart, bir vanan\u0131n yang\u0131na maruz kalma s\u0131ras\u0131nda ve sonras\u0131nda bas\u0131nc\u0131 kontrol edip edemeyece\u011fini test ederek yang\u0131n riski olan tesislerde g\u00fcvenli\u011fi nas\u0131l sa\u011flayaca\u011f\u0131n\u0131z\u0131 g\u00f6sterir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Purpose_and_Scope_of_ISO_10497\"><\/span><strong>ISO 10497&#039;nin Amac\u0131 ve Kapsam\u0131<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Standart, yang\u0131n\u0131n vana b\u00fct\u00fcnl\u00fc\u011f\u00fcn\u00fc tehlikeye atabilece\u011fi end\u00fcstriyel tesislerdeki kritik bir g\u00fcvenlik endi\u015fesini ele almaktad\u0131r. Yang\u0131n olaylar\u0131 s\u0131ras\u0131nda vanalar ar\u0131zaland\u0131\u011f\u0131nda, yan\u0131c\u0131 veya tehlikeli maddeler s\u0131zd\u0131rabilir, yang\u0131n tehlikesini art\u0131rabilir ve ek g\u00fcvenlik riskleri yaratabilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 10497, vanan\u0131n yang\u0131n ko\u015fullar\u0131ndaki bas\u0131n\u00e7 tutma kapasitesini hedefler. Ancak, standart vana tertibat\u0131n\u0131n bir par\u00e7as\u0131 olan manuel olarak \u00e7al\u0131\u015ft\u0131r\u0131lan di\u015fli kutular\u0131 d\u0131\u015f\u0131ndaki akt\u00fcat\u00f6r testlerini kapsamaz. Elektrikli, pn\u00f6matik veya hidrolik akt\u00fcat\u00f6rler ayr\u0131 yang\u0131n koruma \u00f6nlemleri gerektirir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Key_Test_Conditions_and_Procedures\"><\/span><strong>Temel Test Ko\u015fullar\u0131 ve Prosed\u00fcrleri<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Yang\u0131n testi, vanalar\u0131 end\u00fcstriyel yang\u0131n senaryolar\u0131n\u0131 temsil eden ko\u015fullara maruz b\u0131rak\u0131r:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>S\u0131cakl\u0131k Gereksinimleri<\/strong>: Vana, 750\u00b0C ile 1000\u00b0C aras\u0131ndaki s\u0131cakl\u0131klarda tam 30 dakika boyunca alevlerle tamamen \u00e7evrelenmelidir. Bu s\u0131cakl\u0131klar, end\u00fcstriyel tesislerdeki hidrokarbon yang\u0131n ko\u015fullar\u0131na kar\u015f\u0131l\u0131k gelir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Test Kurulumu<\/strong>: Teknisyenler, vanay\u0131 hem g\u00f6vde hem de delik yatay konumda olacak \u015fekilde yatay olarak monte ederler. Bu konum, t\u00fcm vana bile\u015fenlerinde e\u015fit \u0131s\u0131 da\u011f\u0131l\u0131m\u0131 sa\u011flar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Bas\u0131n\u00e7 Testi<\/strong>M\u00fchendisler, vanalar\u0131 iki bas\u0131n\u00e7 seviyesinde test eder. D\u00fc\u015f\u00fck bas\u0131n\u00e7 testlerinde, PN40\/S\u0131n\u0131f 300 veya daha d\u00fc\u015f\u00fck yumu\u015fak oturmal\u0131 vanalar i\u00e7in 0,2 MPa bas\u0131n\u00e7 kullan\u0131l\u0131r. Y\u00fcksek bas\u0131n\u00e7 testlerinde ise, di\u011fer t\u00fcm vana tipleri i\u00e7in 20\u00b0C&#039;de izin verilen maksimum \u00e7al\u0131\u015fma bas\u0131nc\u0131n\u0131n 75% de\u011feri uygulan\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Test S\u0131ras\u0131<\/strong>: 30 dakikal\u0131k yanma s\u00fcresinin ard\u0131ndan, vana, s\u0131cakl\u0131k 100\u00b0C&#039;nin alt\u0131na d\u00fc\u015fene kadar \u00f6l\u00e7\u00fcmlerin devam etti\u011fi bir so\u011fuma a\u015famas\u0131na girer. So\u011fuma s\u00fcresinin ard\u0131ndan, vana, yaln\u0131zca standart \u00e7al\u0131\u015fma kolu veya di\u015fli kutusu kullan\u0131larak kapal\u0131 konumdan tamamen a\u00e7\u0131k konuma getirilerek \u00e7al\u0131\u015f\u0131r durumda kalmal\u0131d\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Performance_Criteria_and_Acceptance_Limits\"><\/span><strong>Performans Kriterleri ve Kabul Limitleri<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 10497, vana boyutuna g\u00f6re de\u011fi\u015fen belirli s\u0131z\u0131nt\u0131 s\u0131n\u0131rlar\u0131 belirler. \u00d6rne\u011fin, DN 50 (2 in\u00e7) \u00e7ap\u0131ndaki bir vana, y\u00fcksek bas\u0131n\u00e7l\u0131 yanma testi s\u0131ras\u0131nda 200 ml\/dakika&#039;y\u0131 ge\u00e7memeli, ayn\u0131 s\u00fcre zarf\u0131nda ise d\u0131\u015f s\u0131z\u0131nt\u0131 50 ml\/dakika ile s\u0131n\u0131rl\u0131d\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Standart, d\u00f6rt kritik performans alan\u0131n\u0131 \u00f6l\u00e7mektedir: yanma s\u0131ras\u0131ndaki yuva s\u0131z\u0131nt\u0131s\u0131, yanma ve so\u011fuma d\u00f6nemlerindeki d\u0131\u015f s\u0131z\u0131nt\u0131, so\u011fuma sonras\u0131 yuva s\u0131z\u0131nt\u0131s\u0131 ve yang\u0131na maruz kald\u0131ktan sonra vana \u00e7al\u0131\u015fabilirli\u011fi. Bu \u00f6l\u00e7\u00fcmler, vanan\u0131n yang\u0131n hasar\u0131ndan sonra bile birincil i\u015flevlerini korudu\u011funu do\u011frular.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u0130\u00e7in <a href=\"https:\/\/www.xintaivalves.com\/tr\/what-is-industrial-gate-valve\/\">end\u00fcstriyel s\u00fcrg\u00fcl\u00fc vanalar<\/a>Genellikle izolasyon hizmetleri i\u00e7in belirtilen bu s\u0131z\u0131nt\u0131 kriterlerinin kar\u015f\u0131lanmas\u0131, yang\u0131n acil durumlar\u0131nda tehlikeli s\u0131v\u0131 s\u0131z\u0131nt\u0131lar\u0131n\u0131n \u00f6nlenmesi a\u00e7\u0131s\u0131ndan \u00f6nemlidir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Qualification_and_Coverage_Rules\"><\/span><strong>Nitelik ve Kapsam Kurallar\u0131<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 10497&#039;nin bir avantaj\u0131, bir vana boyutunun test edilmesiyle birden fazla ilgili boyutun ve bas\u0131n\u00e7 derecesinin de onaylanmas\u0131, b\u00f6ylece g\u00fcvenlik standartlar\u0131n\u0131n korunmas\u0131 ve test maliyetlerinin d\u00fc\u015f\u00fcr\u00fclmesidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DN 50 vana testi, ayn\u0131 tasar\u0131ma sahip t\u00fcm k\u00fc\u00e7\u00fck vanalar\u0131 yeterlilik a\u00e7\u0131s\u0131ndan de\u011ferlendirir. Tersine, daha b\u00fcy\u00fck vanalar\u0131n test edilmesi, belirli s\u0131n\u0131rlar dahilinde daha k\u00fc\u00e7\u00fck vanalar\u0131 yeterlilik a\u00e7\u0131s\u0131ndan de\u011ferlendirebilir. Bas\u0131n\u00e7 de\u011ferleri a\u00e7\u0131s\u0131ndan, test edilen bir vana, standart yeterlilik tablolar\u0131nda belirtilen belirli s\u0131n\u0131rlamalarla, de\u011ferinin iki kat\u0131na kadar daha y\u00fcksek bas\u0131n\u00e7 s\u0131n\u0131flar\u0131n\u0131 yeterlilik a\u00e7\u0131s\u0131ndan de\u011ferlendirir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Malzeme kalifikasyonu da ayn\u0131 \u015fekilde i\u015fler. Ferritik \u00e7elik vanalar\u0131n test edilmesi, ek orta seviye testlerle \u00f6stenitik veya dubleks malzemelerin kalifikasyonunu sa\u011flayabilir. Bu yakla\u015f\u0131m, farkl\u0131 malzemelerin yang\u0131na maruz kalmaya farkl\u0131 tepki verebilece\u011fini kabul ederken, testin pratikli\u011fini de korur.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Practical_Applications_for_Valve_Selection\"><\/span><strong>Vana Se\u00e7imi \u0130\u00e7in Pratik Uygulamalar<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 10497 sertifikas\u0131, rafineriler, kimya tesisleri ve a\u00e7\u0131k deniz platformlar\u0131 gibi yang\u0131na e\u011filimli ortamlar i\u00e7in vana se\u00e7erken kritik \u00f6neme sahiptir. Bu standart, m\u00fchendislerin acil durum kapatma sistemleri, proses izolasyonu ve di\u011fer kritik g\u00fcvenlik fonksiyonlar\u0131 i\u00e7in uygun vanalar\u0131 belirlemelerine yard\u0131mc\u0131 olur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Ayr\u0131nt\u0131l\u0131 bir \u00e7al\u0131\u015fma y\u00fcr\u00fct\u00fcrken <a href=\"https:\/\/www.xintaivalves.com\/tr\/blog\/a-complete-guide-to-test-a-swing-type-check-valve\/\">vana test prosed\u00fcrleri<\/a>Yang\u0131n testleri, standart operasyonel testlerin \u00f6tesinde bir g\u00fcvenlik kontrol\u00fc daha sa\u011flar. Bu, \u00f6zellikle acil durumlarda g\u00fcvenilir \u00e7al\u0131\u015fman\u0131n kritik \u00f6nem ta\u015f\u0131d\u0131\u011f\u0131 yang\u0131n suyu sistemlerindeki \u00e7ek valfler i\u00e7in \u00f6nemlidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Yang\u0131n g\u00fcvenli\u011fi sertifikas\u0131 ayr\u0131ca bak\u0131m planlamas\u0131n\u0131 ve acil durum m\u00fcdahale prosed\u00fcrlerini de etkiler, \u00e7\u00fcnk\u00fc tesis operat\u00f6rleri yang\u0131n olaylar\u0131 s\u0131ras\u0131nda vana performans\u0131na g\u00fcvenebilirler.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><span class=\"ez-toc-section\" id=\"Manufacturing_Excellence_for_Fire_Safe_Applications\"><\/span><strong>Yang\u0131na Dayan\u0131kl\u0131 Uygulamalar i\u00e7in \u00dcretim M\u00fckemmelli\u011fi<\/strong><span class=\"ez-toc-section-end\"><\/span><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Xintai Valve olarak, \u00fcretim s\u00fcre\u00e7lerimiz tasar\u0131mdan teste kadar yang\u0131n g\u00fcvenli\u011fi hususlar\u0131n\u0131 i\u00e7erir. Vana \u00fcretiminde 25 y\u0131l\u0131 a\u015fk\u0131n deneyimimizle, personel ve tesislerin korunmas\u0131nda yang\u0131n g\u00fcvenli\u011fi performans\u0131n\u0131n \u00f6nemini anl\u0131yoruz. Kalite kontrol sistemlerimiz, yang\u0131na dayan\u0131kl\u0131 vanalar\u0131n hem ISO 10497 gerekliliklerini hem de zorlu end\u00fcstriyel uygulamalar i\u00e7in \u00f6zel m\u00fc\u015fteri g\u00fcvenlik standartlar\u0131n\u0131 kar\u015f\u0131lamas\u0131n\u0131 sa\u011flar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><br><\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>ISO 10497 fire safe valve testing is an international standard that specifies fire testing requirements for valves. This standard shows you how to test whether a valve can contain pressure during and after fire exposure, ensuring safety in facilities where fire is a risk. Purpose and Scope of ISO 10497 The standard addresses a critical [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":13708,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3],"tags":[],"class_list":["post-13707","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"_links":{"self":[{"href":"https:\/\/www.xintaivalves.com\/tr\/wp-json\/wp\/v2\/posts\/13707","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.xintaivalves.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.xintaivalves.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.xintaivalves.com\/tr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.xintaivalves.com\/tr\/wp-json\/wp\/v2\/comments?post=13707"}],"version-history":[{"count":1,"href":"https:\/\/www.xintaivalves.com\/tr\/wp-json\/wp\/v2\/posts\/13707\/revisions"}],"predecessor-version":[{"id":13709,"href":"https:\/\/www.xintaivalves.com\/tr\/wp-json\/wp\/v2\/posts\/13707\/revisions\/13709"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.xintaivalves.com\/tr\/wp-json\/wp\/v2\/media\/13708"}],"wp:attachment":[{"href":"https:\/\/www.xintaivalves.com\/tr\/wp-json\/wp\/v2\/media?parent=13707"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.xintaivalves.com\/tr\/wp-json\/wp\/v2\/categories?post=13707"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.xintaivalves.com\/tr\/wp-json\/wp\/v2\/tags?post=13707"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}