플랜지형 게이트 밸브 사용 시 주의사항은 무엇입니까?

플랜지형 게이트 밸브 provide robust on/off control for critical piping systems across countless industrial applications. However, their unique operating characteristics require some key precautions to ensure safe, reliable performance over the valve’s service life. 

Failure to follow proper procedures can lead to hazardous leaks, unintended valve movement, or catastrophic failures with disastrous consequences.

Potential Hazards of Improper Gate Valve Use

While gate valves excel at robust isolation, there are some inherent risk factors to be aware of:

  1. Trapped Pressure

Gate valve designs feature a cavity between the gate and valve body where process fluid can become trapped. This creates a dangerous buildup of pressure if not properly vented before maintenance.

  1. Gate Jamming/Binding

Over time, debris, scaling or baked-on solids can cause the gate to stick or bind within the valve body restricting operation. This can prevent tight shutoff and lead to leaks.

  1. Valve Stem Blowout

The rising valve stem design of gate valves means shut-off forces act directly on the stem. Failing to relieve this force could allow the gate and stem to eject like a projectile when disassembled.

  1. Installation Misalignment

Improper alignment or uneven gasket loading when installed can quickly deteriorate seat surfaces resulting in fugitive emissions and leaks.

Proper Installation and Operating of Gate Valve

How should the maintenance of the flanged gate valves be carried out? Following some straightforward installation and operating practices can mitigate these potential hazards of flanged gate valves:

  1. Installation Alignment

Gate valves must be installed with the centerlines of the inlet/outlet and valve bore in perfect alignment. Use precision shims or milled gaskets to avoid cocked/skewed positions.

  1. Gasket Selection

Always use full circumference gaskets sized to the raised face dimensions per code requirements. Spiral-wound gaskets may be required for high temperatures.

  1. Torque Procedures

Follow the manufacturer’s specified bolt torquing sequence and values – do not over or under tighten flange hardware. Periodically recheck to maintain proper compression.

  1. Pressure Relief

NEVER attempt to dismantle a flanged gate valve with trapped pressure in the body cavity. Always provide a venting system with upstream and downstream drain ports.

  1. 매끄럽게 하기

Lubricate gate valve stems and stem bushings regularly to prevent binding or galling. The proper lubricant prevents damage and maximizes operating cycles.

  1. Cycle Testing

Partially opening and then reclosing a gate valve can cause the gate to jam and should be avoided. Only operate fully open or fully closed.

  1. Gate Protection

Keep the gate in the open position when not providing isolation. Closed gates can incur damage from continuous flow impingement.

결론

Ultimately, sourcing flanged gate valves from a proven manufacturer that adheres to global standards provides the foundation for safe, reliable performance. Premium materials, engineered designs and proper pressure/temperature ratings suited for your application are essential.